Distributor Links
Quick Search

Product Temperature Ranges Vs. Power Sources

    Power Sources
Product Family Base ProductTemp Range AC-DC adapter
(-10° to +50° C)
IE-Power/5V
(-20° to +70° C)
IE-PowerTray/18
(-20° to +70° C)
Dual
USB cable
Single
USB cable
PoE (PD)
               
  Maximum            
MiniMC 0° to +50° C  
Giga-MiniMC 0° to +50° C    
MiniMc-Gigabit 0° to +50° C    
               
  w/ DC Power            
IE-MiniMC -25° to +85° C  
IE-Giga-MiniMC -25° to +85° C    
IE-MiniFiberLinX-II -25° to +85° C  
IE-ModeConverter -25° to +85° C    

 

iMcV-DS3/E3-LineTerm

iMcV-DS3/E3-LineTerm

Click on image to close

iMcV-DS3/E3-LineTerm

iMcV-DS3/E3-LineTerm is an SNMP manageable module that converts standard thin coax signals (DS3, E3, STS-1) to a single-mode or multi-mode fiber signal, extending the distance of data transmissions over MAN access networks up to 80 km. The iMcV-DS3/E3/STS-LineTerm converter is perfect for service providers and enterprise campus networks utilizing DS3/E3/STS-1 coaxial circuits.

It performs the standard "Line Termination" (GR-820-CORE) function of these TDM-based line signals. This function transmits an Alarm Indication Signal (AIS) on the line whenever a received signal is lost. Line faults can easily be isolated to one line section and do not propagate over multiple-line sections as they do with normal line repeaters.

Each module includes one pair of BNC connectors and one pair of ST or SC fiber optic connectors. This module can be installed in any iMediaChassis or MediaChassis chassis, but can only be managed through a SNMP manageable iMediaChassis.

It is also available with single-strand fiber and the iMcV-DS3/E3-LineTerm BNC/SSFX modules allow two wavelengths (1310 nm and 1550 nm) to share one fiber strand, essentially doubling the capacity of installed fiber. The single-strand versions at HOST and REMOTE must have opposite transmit and receive wavelengths. For example, one that transmits at 1310 nm must be paired with another that receives at 1310 nm.

iMcV-DS3/E3-LineTerm modules are deployed in pairs (one at each end of a fiber line). The data transmitted on the fiber ports can only be received and interpreted by another iMcV-DS3/E3-LineTerm unit.

 

 

 

 

 

 

Application Diagram Features & Specifications Support Documents Ordering Information

 

Features and Specifications

  • Protocol-selectable operation - Operates at DS3 (45 Mbps), E3 (34 Mbps) or STS-1 (52 Mbps) protocols
  • Includes two modes of operation for loopback testing (fiber loopback and coax loopback)
  • Supports LIU Waveshape - switch selectable optimal transmit waveshape for the line build-out distance on the coax line.
  • Automatic MDI-II/MDI-X
  • Hot-swappable architecture
  • Supports GUI-based iView²
  • Includes diagnostic and status LEDs

 

DS3, E3, STS-1 Interface:

  • BNC coax 75 +/- 5% ohms
  • DS3 (44.736 Mbps +/- 20 ppm)
  • E3 (34.368 Mbps +/- 20 ppm)
  • STS-1 (51.840 Mbps +/- 20 ppm)

Supported Fiber Types:

  • 50/125µm or 62.5/125µm multi-mode fiber cabling
  • 9/125µm single-mode fiber cabling
  • Single-strand fiber

Physical:

  • Connectors: BNC for coax, and ST or SC for fiber
  • One coaxial port, one fiber port

Standards Compliance (DS3, E3, STS-1):

  • ANSI T1.102-1993
  • ANSI T1.107.1995
  • GR-820-CORE

Regulatory Approvals:

  • FCC Class A
  • UL/CuL
  • CE

Operating Temperature:

+32° to +122° F (0° to +50° C); 5% to 95% (non-condensing); 0 to 10,000 ft. altitude

Storage Temperature:

+13° to +160° F (-25° to +70° C); 5% to 95% (non-condensing); 0 to 10,000 ft. altitude

Power Rating:

0.55 Amps @ 5.0 V

Dimensions:

Single Slot iMcV module

Shipping Weight:

0.30 lbs (0.11 kg)

 

 

For more information about RoHS and for RoHS product availability, please contact sales@imcnetworks.com

 

iMcV-DS3/E3-LineTerm Documents

Certification

Data Sheet

Manuals and Installation Guides

 

Standard

SKU Description Power Budget Distance
850-14400 iMcV-DS3/E3-LineTerm, BNC/FX-MM1300-ST
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-MM1300-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
DPX, 1300, MM, ST, 1X9, 3.3V, 155Mbps, XT, -20/-14/-32, 5Km Multi-mode -20 -14 -32 12 -8
2 km
850-14401 iMcV-DS3/E3-LineTerm, BNC/FX-MM1300-SC
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-MM1300-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
DPX, 1300, MM, ST, 1X9, 3.3V, 155Mbps, XT, -20/-14/-32, 5Km Multi-mode -20 -14 -32 12 -8
2 km
850-14402 iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/PLUS-ST
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/PLUS-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/PLUS - 100 Mbps Single-mode -15 -8 -36 21 -3
40 km
850-14403 iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/PLUS-SC
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/PLUS-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/PLUS - 100 Mbps Single-mode -15 -8 -36 21 -3
40 km
850-14404 iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/LONG-ST
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/LONG-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/LONG Singlemode -5 0 -36 31 -3
80 km
850-14405 iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/LONG-SC
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-SM1310/LONG-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/LONG Singlemode -5 0 -36 31 -3
80 km
850-14406 iMcV-DS3/E3-LineTerm, BNC/FX-SM1550/LONG-SC
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-SM1550/LONG-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550/LONG Singlemode -5 0 -36 31 -3
80 km
850-14438 iMcV-DS3/E3-LineTerm, BNC/FX-MM850-ST
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-MM850-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
MM850 - 100 Mbps Multi-mode -10 -4 -24 14 0
2 km
850-14439 iMcV-DS3/E3-LineTerm, BNC/FX-MM850-SC
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/FX-MM850-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
MM850 - 100 Mbps Multi-mode -10 -4 -24 14 0
2 km

 

Single-Strand Fiber

SKU Description Power Budget Distance
850-14410 iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1310-SC (1310xmt/1550rcv)
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1310-SC (1310xmt/1550rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310 BiDi -13 -6 -33 20 -3
20 km
850-14411 iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1550-SC (1550xmt/1310rcv)
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1550-SC (1550xmt/1310rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550 BiDi -13 -6 -33 20 -3
20 km
850-14412 iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1310/PLUS-SC (1310xmt/1550rcv)
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1310/PLUS-SC (1310xmt/1550rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/PLUS - 100 Mbps BiDi -5 0 -34 29 -3
40 km
850-14413 iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1550/PLUS-SC (1550xmt/1310rcv)
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1550/PLUS-SC (1550xmt/1310rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550/PLUS BiDi -5 0 -34 29 -3
40 km
850-14414 iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1310/LONG-SC (1310xmt/1550rcv)
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1310/LONG-SC (1310xmt/1550rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/LONG - 100 Mbps BiDi -3 2 -34 31 -3
60 km
850-14415 iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1550/LONG-SC (1550xmt/1310rcv)
Click to View

Fiber Power Budget for iMcV-DS3/E3-LineTerm, BNC/SSFX-SM1550/LONG-SC (1550xmt/1310rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550/LONG BiDi -3 2 -34 31 -3
60 km