Distributor Links
Quick Search

Product Temperature Ranges Vs. Power Sources

    Power Sources
Product Family Base ProductTemp Range AC-DC adapter
(-10° to +50° C)
IE-Power/5V
(-20° to +70° C)
IE-PowerTray/18
(-20° to +70° C)
Dual
USB cable
Single
USB cable
PoE (PD)
               
  Maximum            
MiniMC 0° to +50° C  
Giga-MiniMC 0° to +50° C    
MiniMc-Gigabit 0° to +50° C    
               
  w/ DC Power            
IE-MiniMC -25° to +85° C  
IE-Giga-MiniMC -25° to +85° C    
IE-MiniFiberLinX-II -25° to +85° C  
IE-ModeConverter -25° to +85° C    

 

iMcV-T1/E1/J1-LineTerm

iMcV-T1/E1/J1-LineTerm

Click on image to close

iMcV-T1/E1/J1-LineTerm

The iMcV-T1/E1/J1-LineTerm is an SNMP manageable module that converts copper-based circuits (T1/E1/J1) to a single-mode or multi-mode fiber signal, extending the distance of data transmissions over networks up to 80 km. The iMcV-T1/E1/J1-LineTerm converter is perfect for service providers and enterprise campus networks utilizing T1/E1/J1 copper lines.

Line Termination Functionality

This module performs the standard "Line Termination" (GR-820-CORE) function of TDM-based line signals. This function transmits an Alarm Indication Signal (AIS) on the line whenever a received signal is lost. Line faults can easily be isolated to one line section and do not propagate over multiple-line sections as they do with normal line repeaters.

Hot-Swappable

Hot-swappable, iMcV-T1/E1/J1-LineTerm modules significantly reduce operation costs by allowing other modules within the same conversion chassis to remain up and running during network upgrades and maintenance. iMcV-T1/E1/J1-LineTerm modules install in any iMediaChassis or MediaChassis series.

Convenient DIP Switch Configuration

This converter series features a protocol-selectable operation to easily choose between T1/J1 and E1 rates via DIP switches located on the board. In addition, a DTE/DCE switch is conveniently located on the front of the unit to simplify cable connections.

Powerful Testing and Troubleshooting Features

To aid in network testing and troubleshooting, the T1/E1/J1-LineTerm features three different loopback test modes: copper loopback, fiber loopback and internal fiber loopback, to allow easy isolation of cable faults. The module also features a Transmit Data Source diagnostic tool which allows operators to choose from three specific patterns of data to identify transmission problems: transmit unframed all ones, transmit a pattern of alternating ones and zeros, and transmit a Pseudorandom Bit Sequence. In addition, the modules have built-in PRBS signal receivers, to simplify testing. All test modes are configurable remotely via iView² SNMP software or locally through DIP switches on the units.

Easy Remote Management and Configuration

The iMcV-T1/E1/J1-LineTerm is easy to install, configure and manage with iView² SNMP application software, or with any other SNMP application such as HP OpenView™. iView² runs: standalone on Windows NT/XP/2000; as a standalone Java Application for other operating systems; as a snap-in module for HP OpenView; as a Web Server running under IIS or as a Java Web Servlet. The advantage of remote management allows the network manager to monitor, configure and troubleshoot units located at the customer site without having to access the remote network. Furthermore, because the remote management technology is not in-band, the T1/E1/J1 converters transmit data at full bit rate while remaining transparent to data channels.

iMcV-T1/E1/J1-LineTerm modules are deployed in pairs (one at each end of a fiber line). The data transmitted on the fiber ports can only be received and interpreted by another iMcV-T1/E1/J1-LineTerm unit.

IMC Networks also offers an iMcV-T1/E1/J1 without the “Line Termination” functionality, operating more as a traditional repeater. For more information visit the iMcV-T1/E1/J1 product page.

 

Application Diagram Features & Specifications Support Documents Ordering Information

 

Features and Specifications

  • Protocol-Selectable — Operates at T1/J1 (1.544 Mbps) and E1 (2.048 Mbps) protocols
  • Supports Alarm Indication Signals (AIS)
  • Internal Test Head Function (PRBS, 1/0, All 1’s)
  • Ability to manage remote unit from host end
  • Supports fiber and copper Loopback
  • Selectable line buildout (0 - 655 ft.)
  • Includes DTE/DCE switch on converter
  • Installs in any iMediaChassis or MediaChassis chassis*
  • Supports GUI-Based iView²
  • CSU Line Gain (7.5, 15, 22.5 db)
  • Monitor Boost (20, 26, 32 db)
  • Supports secondary line protection

 Supported Fiber Types:

  • 50/125µm or 62.5/125µm multi-mode fiber cabling
  • 9/125µm single-mode fiber cabling

Physical:

  • Connectors: RJ-48 and ST or SC
  • Single-strand fiber

Standards Compliance:

  •  ANSI T1.102-1993
  • ANSI T1.107-1995
  • GR-820-CORE

 Regulatory Approvals:

  • FCC Class A
  • UL/CuL
  • CSA
  • CE

Operating temperature:
+32° to +122° F (0° to +50° C); 5% to 95% (non-condensing), 0 - 10,000 ft. altitude

Storage Temperature:
-13° to +158° F (-25° to +70° C); 5% to 95% (non-condensing), 0 - 10,000 ft. altitude

Power Rating:

580mA at 5V

Dimensions:

Standard single-slot chassis module

Shipping Weight:

0.30 lbs (0.11 kg)

 

* For DC-powered telco environments, it is not recommended that the iMcV-DS3/E3/STS-1 repeater be installed in an IE-MediaChassis/1. The power source in this chassis is not isolated, and cannot support positive ground reference systems typically used in Telco environments. The IE-MediaChassis/2-DC, MediaChassis/2-DC and the iMediaChassis family are suitable alternatives.

 

iMcV-T1/E1/J1-LineTerm Documents

Certification

Data Sheet

Manuals and Installation Guides

 

Standard

SKU Description Power Budget Distance
850-14101 iMcV-T1/E1/J1-LineTerm TP/Fiber-MM850-ST
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-MM850-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
MM850 - 100 Mbps Multi-mode -10 -4 -24 14 0
2 km
850-14102 iMcV-T1/E1/J1-LineTerm TP/Fiber-MM850-SC
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-MM850-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
MM850 - 100 Mbps Multi-mode -10 -4 -24 14 0
2 km
850-14103 iMcV-T1/E1/J1-LineTerm TP/Fiber-MM1300-ST
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-MM1300-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
DPX, 1300, MM, ST, 1X9, 3.3V, 155Mbps, XT, -20/-14/-32, 5Km Multi-mode -20 -14 -32 12 -8
5 km
850-14104 iMcV-T1/E1/J1-LineTerm TP/Fiber-MM1300-SC
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-MM1300-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
DPX, 1300, MM, ST, 1X9, 3.3V, 155Mbps, XT, -20/-14/-32, 5Km Multi-mode -20 -14 -32 12 -8
5 km
850-14105 iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/PLUS-ST
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/PLUS-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/PLUS - 100 Mbps Single-mode -15 -8 -36 21 -3
40 km
850-14106 iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/PLUS-SC
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/PLUS-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/PLUS - 100 Mbps Single-mode -15 -8 -36 21 -3
40 km
850-14107 iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/LONG-ST
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/LONG-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/LONG Singlemode -5 0 -36 31 -3
40 km
850-14108 iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/LONG-ST
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/LONG-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/LONG Singlemode -5 0 -36 31 -3
40 km
850-14110 iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1550/LONG-ST
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1550/LONG-ST

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550/LONG Singlemode -5 0 -36 31 -3
80 km
850-14111 iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1550/LONG-SC
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1550/LONG-SC

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550/LONG Singlemode -5 0 -36 31 -3
80 km

 

Single-Strand Fiber

SKU Description Power Budget Distance
850-14120 iMcV-T1/E1/J1-LineTerm TP/SSFiber-MM1310-SC (1310xmt/1550rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-MM1310-SC (1310xmt/1550rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310 BiDi -13 -6 -33 20 -3
2 km
850-14121 iMcV-T1/E1/J1-LineTerm TP/SSFiber-MM1550-SC (1550xmt/1310rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-MM1550-SC (1550xmt/1310rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550 BiDi -13 -6 -33 20 -3
2 km
850-14122 iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310-SC (1310xmt/1550rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310-SC (1310xmt/1550rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310 BiDi -13 -6 -33 20 -3
20 km
850-14123 iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550-SC (1550xmt/1310rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550-SC (1550xmt/1310rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550 BiDi -13 -6 -33 20 -3
20 km
850-14124 iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310/PLUS-SC (1310xmt/1550rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310/PLUS-SC (1310xmt/1550rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/PLUS - 100 Mbps BiDi -5 0 -34 29 -3
40 km
850-14125 iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550/PLUS-SC (1550xmt/1310rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550/PLUS-SC (1550xmt/1310rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550/PLUS BiDi -5 0 -34 29 -3
40 km
850-14126 iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310/LONG-SC (1310xmt/1550rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310/LONG-SC (1310xmt/1550rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1310/LONG - 100 Mbps BiDi -3 2 -34 31 -3
60 km
850-14127 iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550/LONG-SC (1550xmt/1310rcv)
Click to View

Fiber Power Budget for iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550/LONG-SC (1550xmt/1310rcv)

Description Interface Min TX Power Max TX Power Min RX Power Power Budget Saturation
SM1550/LONG BiDi -3 2 -34 31 -3
60 km